Feedback

Second ONT Requests

When a customer already has one ONT installed and is requesting a second ONT

Overview

Use this process when a customer already has one ONT installed and is requesting a second ONT. Additionally, Chorus will advise if a third ONT or an infill is needed.

Remember, the Multiple Primary process allows you to activate a second, third, or even fourth broadband service on an existing ONT without needing an additional ONT installed. The second ONT process should only be used when a Multiple Primary order does not meet your customer’s needs.
 

What you need to know:

  • A second ONT is considered to be a new install and currently all associated costs are free. If the customer requires other work, you must ensure the "While You Are Here” field under Offer Characteristics, Standard CSE is set to Yes, and also select any additional work required, to avoid delays to the customer.
  • Second ONTs may be installed into an auxiliary building.
  • The second ONT can be assigned to a different account or RSP.
  • There is currently no charge from Chorus for a second ONT installation using this process, except build and material costs purchased by the customer (e.g. labour if the customer chooses to have external work prior to the Chorus technician’s arrival).  
  • If the technician determines on arrival that a different type of install is required then charges may apply (e.g. infill). This will only happen if the information provided by the customer is incorrect.
  • If the second ONT is to be installed in a separate building, the customer must provide a conduit with a draw/hybrid cable between the existing termination point in the main house, and where the Fibre is to be installed in the auxiliary building.  The customer can choose to do this themselves or contract to a builder – we may provide the cabling based on the request. See steps 9 and 11 of this process for details. 
     

Ordering Process
 

Request a Secondary ONT  

Follow these steps to identify a possible second ONT request or if you need help to determine if it’s a second/third ONT or infill:

  • This process is for Residential customers only.
  • Each address has been designed to have two connections. Third and subsequent ONT requests, Infill Build, or Last Step Fibre will incur charges.  
  • If on arrival the technician determines this is an infill build scenario, the order will be cancelled by the Chorus technician, and you will need to submit a new order for the correct install type.  
  • Infill build charge includes new drop off and installation of ONT. No additional charges would apply to the infill order.
  • A building would be considered a minor dwelling (and subject to infill build) if it is self-contained with a separate kitchen, bathroom facilities and own separate power meter. Otherwise, it is classed as an auxiliary building e.g., garage or sleep out.
     
ONT next to primary  
  1. Create an additional ONT order in the Chorus Portal.  
    Note: If the address is valid, the Chorus portal will confirm that a spare fibre is available. If no spare fibre is available, you will be alerted that it’s "not feasible to order" and request ends. If the customer wishes to proceed, you will need to request a price on application.
  2. Ask the customer: “Will the second ONT be installed in a different building?”
    If yes, go to step 7.
    If no, go to step 3.
  3. Ask the customer: “Is the second ONT to be installed next to the primary ONT?”
    If yes, go to step 4.
    If no, go to step 5.
  4. Within your order, add full work instructions into Location of Equipment field to allow the Chorus technician to schedule appropriate time for the order. E.g. Second ONT to be installed next to primary. The Chorus technician will carry out a scope and discuss requirements with customer prior to installation. There is currently no cost to customer.  
    Important:  If “While You Are Here” is required you must select any additional activities, i.e., additional jackpoint, or the Chorus technician will refer customer back for approval before proceeding, charges apply.
     
ONT installation in the same building, modem in a different location
  1. Ask the customer: “Is the second ONT to be installed in the same building but the modem in a different location?”
    If yes, go to step 6.
    If no, go to step 7.
  2. Ask the customer: “Is there a reasonable pathway, i.e. through roof space?”  
    Note: See the Troubleshooting section for what to check.
  3. Within your order, add full work instructions into Location of Equipment field to allow the technician to schedule appropriate time for the request (e.g. modem to be installed bedroom 1 on 1st floor). 
    The Chorus technician will carry out a scope and discuss requirements with customer prior to installation. Chorus will supply and install cabling from existing ONT to new location. There is currently no cost to customer.
    Note: If the customer has specific requirements e.g., cabling must go through a wall cavity, it is recommended that the customer engages with an electrician to carry out this work prior to the Chorus technician arrival as this is not a Chorus technicians area of expertise.  Work carried out by the electrician will be at the customer’s expense.
    Important:  If “While You Are Here“ is required you must select any additional activities, i.e., additional jackpoint, or the Chorus technician will refer customer back for approval before proceeding, charges apply.
     
Modem installation, different building
  1. Ask the customer: Is the second ONT to be installed next to the primary ONT, and the modem to be installed in an auxiliary building less than 100m away?
    If yes, go to step 8.
    If no, go to step 10.
  2. Within the order, add full work instructions into Location of Equipment field to allow the Chorus technician to schedule appropriate time for the request e.g., Modem to be installed in separate building i.e., garage, sleep out, office or shed.
    Important: If “While You Are Here” is required, you must select any additional activities (i.e additional jackpoint), or the Chorus technician will refer the customer back for approval before proceeding(charges apply).
  3. Prior to technician arrival, advise the customer that they must:
    - arrange trench,
    - install outdoor grade ducting, and  
    - supply/install a connectorised RJ45 CAT cable from the existing ONT position to modem location.
    For purchasing duct and cabling:
    Outdoor grade 20mm duct must be purchased from any electrical wholesaler (e.g. Ideal Electrical or Corys). Ducting can be any colour EXCEPT red or orange.
    CAT cabling can be purchased from any technology store (e.g. Noel Leeming, PB Tech) and installed by an electrician. 
    The Chorus technician will carry out a scope and discuss requirements with customer prior to installation.  There is currently no installation cost to customer, other than purchases made for connecting CAT cable and ducting, or if the customer chooses to contract the digging of the trench to a builder.
    Notes:
    - Power can be placed in the same trench, but not the same duct. Ensure ECP34 (Electrical code of practice) clearances are adhered to.
    - Advise the customer to contact B4UDIGprior to digging to ensure no other services are impacted. Full guidelines can be found  here.
    - TCF recommend CAT6a cabling and above dependent on customer’s budget.
     
ONT installation, different building
  1. Ask the customer: “Is the second ONT to be installed into an auxiliary building that has no registered postal address?”
    If yes, go to step 11.
    If no, go to step 12.
    Important: If building is greater than 200m from the primary ONT, then the Last Step Fibre Build process applies.
  2. Within the order, add full work instructions into the ‘Location of Equipment’ field to allow the Chorus technician to schedule an appropriate time for the request (e.g. ONT to be installed in separate building, such as a garage, sleep out, office or shed).
    Important:
    - If “While You Are Here” is required, you must select any additional activities (i.e. additional jackpoint) or the Chorus technician will refer the customer back for approval before proceeding, charges apply.
    - If building is greater than 200m from primary ONT then Last Step Fibre Build rules apply.
    - Power can be placed in the same trench, but not the same duct, ensure ECP34 (Electrical code of practice) clearances are adhered to.
    Learn more about development guidelines.
    Explain the following options for installation to the customer:
OptionAction
Option 1) The customer can arrange for a 450mm deep trench, supply and install outdoor grade ducting with draw wire from existing ETP to new location prior to technician arrival, who will then install the fibre and connect the second ONT.  Advise the customer they will need to:
- Purchase outdoor grade 20mm duct themselves, which is available at any electrical wholesaler e.g., Ideal Electrical or Corys.
- Ducting can be any colour EXCEPT red or orange, and all purchases are at the customer’s cost.
Note: Chorus will provide the fibre cable at the time of installation.
Advise customer to contact B4UDIG  prior to digging to ensure no other services are impacted.

Option 2) They can arrange a 200mm deep open trench from the existing ETP to the new ONT location, prior to the Chorus technician’s arrival when they will install ruggedised fibre. No ducting is required for ruggedised fibre, and the Chorus Technician will provide and install ruggedised fibre within the open trench.

 

Advise the customer to contact B4UDIG  prior to digging, to ensure no other services are impacted.
In both cases, the Chorus technician will carry out a scope and discuss requirements with customer prior to installation, and while the customer will need to pay for any resources they purchase like ducting, or if they contract digging the trench to a builder, currently no installation costs will be charged to the customer by Chorus (including Fibre cable).

 

Infill redirect
  1. Ask the customer: “Has the premise been officially sub-divided with own power meter and does it have a registered postal address?”

    IfThen
    No

    Advise the customer they can proceed with the installation of the second ONT. However, there is a risk if a fault occurs at the primary ONT in the future and if they have not followed the infill process, this could cause delays in rectifying the fault due to access to the primary ONT.

    Confirm they are happy to go ahead with this understanding, and if:

    • Yes, go to step 11.
    • No, then if the customer does not wish to officially subdivide or accept the risk, a second ONT cannot be installed.

    Notes:  
    The RSP will discuss alternative options.
    Customers need to provide evidence of a registered postal address. The address will be created in AMA and then an order can be placed. Accepted evidence is a screen shot from NZ Post website and electricity authority or utility bill.

    Yes

    Go to step 13.

    Important: If building is greater than 200m from the primary ONT then Last Step Fibre Build rules apply.

  2. Confirm that the address exists in the Chorus portal, and if:
    Yes, go to step 16.
    No, go to step 14.
  3. Ask the customer to provide evidence of the postal address from NZ Post website and electricity authority or utility invoice.  A screen shot from NZ Post website is sufficient.
  4. Once the customer has provided evidence, create an Address Validation request via the Chorus portal.  Once the address has been created, then the Connection Order can be submitted.
  5. Refer to the Infill Build process.  If the building is greater than 200m from the boundary then the Last Step Fibre Build rules apply.
     

Troubleshooting scenarios

The following troubleshooting information provides specific scenarios to help clarify the previous process steps. 

IfThen
  1. Second ONT is to be installed in the same building, at the same location
  • Submit a request for an additional ONT. Add instructions to the ‘Location of Equipment’ field to allow the Chorus technician to schedule an appropriate time for the request (e.g. "ONT to be installed next to existing").
  • If “While You Are Here” is required, select any additional activities (i.e., additional jackpoint, or the Chorus technician will refer customer back to RSP for approval.)
    • Currently, there is no cost to the customer for a second ONT but charges apply for any “While You Are Here” options. 
  1. Second ONT to be installed next to primary ONT in the same building but at a different location, which is less than 100m from second ONT (i.e. bedroom or garage).

    Confirm with the customer that there is a reasonable pathway, (if known) this includes:
  • through wall cavity
  • under floor
  • through roof space
  • exterior of main building via surface mount from ONT to modem location if acceptable with the customer.

Note: If the customer has specific requirements, we recommended this work is carried out by an electrician, as this is not a Chorus technician area of expertise.  CAT cabling can be purchased from any electrical store (e.g. Noel Leeming, PB Tech or electrician will supply).

Return to step 6  ONT installation in the same building, modem in a different location.

  • Submit a request for an additional ONT.
  • Add instructions to the Location of Equipment field, to allow the Chorus technician to schedule an appropriate time for the request (e.g. "Modem to be installed bedroom 1 on 1st floor”).
  • If “While You Are Here” is required, select any additional activities (i.e. additional jackpoint), or the Chorus technician will refer the customer back to the RSP for approval.
  • Chorus will supply and install cabling from the existing ONT to new modem location.

Note: TCF recommend using CAT6a and above depending on the customer's budget.

 Currently, there is no cost to the customer for a second ONT but charges apply for any “While You Are Here”.

Learn more about premises wiring cable guidelines 

  1. Second ONT is to be installed in a different location within the same building.

    Confirm with customer that there is a reasonable pathway (if known) this includes:
  • through wall cavity
  • under the floor
  • through roof space
  • exterior of main building via surface mount from ETP to secondary ONT location if acceptable with the customer.

Note: If the customer has specific requirements, it is recommended this work is carried out by an electrician as this is not a Chorus technician area of expertise.  Electrician will supply composite cable. 

  • Submit request for additional ONT.
  • Add instructions to the Location of Equipment field to allow the Chorus technician to schedule appropriate time for the request (e.g. "ONT to be installed bedroom 1").
  • If “While You Are Here” is required, select any additional activities (i.e. additional jackpoint), or Chorus technician will refer customer back to RSP for approval.

Note: Chorus will supply and install composite cable from the existing ETP to new ONT location.

Learn more about premises wiring cable guidelines

Currently, there is no cost to the customer for a second ONT but charges apply for any “While You Are Here” options. 

  1. Second ONT is to be installed next to a Primary ONT and modem in an auxiliary building less than 100m from second ONT, such as:
  • Garage
  • Sleep out (not self-contained)
  • Office
  • Shed/workshop.

The Building:

  • has no separate power meter and is owned by the primary ONT account holder.
  • does not have its own letter box or postal address.

This scenario includes voice over ATA.

Note:  If the customer wants an additional ethernet connectivity away from the modem, then “While You Are Here” charges apply.

  • Submit a request for an additional ONT.
  • Add full work instructions into Location of Equipment field allow the Chorus technician to schedule appropriate time for the request (e.g. Modem to be installed in separate building garage, sleep out, office or shed).
  • If “While You Are Here” is required, select any additional activities (i.e., additional jackpoint), or the Chorus technician will refer customer back to RSP for approval.
  • Customer must arrange trench / ducting for cabling and supply / install connectorised RJ45 cable from the existing ONT to modem location prior to arrival.
  • Cabling can be purchased from any electrical store, e.g., Noel Leeming or PB Tech.
  • TCF recommend using CAT6a and above depending on the customer’s budget.
  • Builder or customer can supply trench, and cabling can be done by an electrician.

Ducting & Trenching Requirements:

  • Install 20mm duct between the two locations at a depth of 450mm.
  • Any suitable duct is acceptable, except orange or red, and must be outdoor grade.
  • 20mm duct can be purchased from any electrical wholesaler e.g., Ideal Electrical or Corys.  Learn more about Chorus trenching guidelines

Advise the customer to contact B4UDIG prior to digging to ensure no other services are impacted.

Power can be placed in the same trench, but not the same duct, ensure ECP34 (Electrical code of practice) clearances are adhered to.

Note: If customer wishes to use voice over ATA, an additional connectorised cable must be installed within the duct prior to technician arrival.

Currently, there no cost to customer for a second ONT but charges apply for any “While You Are Here” options. 

  1. Second ONT to be installed in an auxiliary building less than 200m from the primary ONT, such as:
  • Garage
  • Sleep out (not self-contained)
  • Office
  • Shed/Workshop.

Where the building:

  • has no separate power supply and is owned by the primary ONT account holder.
  • does not have own letter box or postal address.

This scenario includes voice over ATA.

Note: If the building is greater than 200m from primary ONT, then Last Step Fibre Build rules apply.

  • Submit request for additional ONT.
  • Add full work instructions to the Location of Equipment field to allow the Chorus technician to schedule appropriate time for the request. e.g. Second ONT to be installed in separate building garage, sleep out, office or shed.
  • If “While You Are Here” is required, select any additional activities (i.e., additional jackpoint), or the Chorus technician will refer customer back to RSP for approval.
  • Customer must arrange trench / ducting and draw wire from existing ETP to new location prior to Chorus technician arrival who will install the fibre.

Trenching options & requirements:

1) Customer to install 20mm duct between the two ETP locations with draw wire within 450mm deep trench.

2) Ruggedised fibre:

  • Customer to dig and leave trench open between two ETP locations at 200mm deep.
  • No ducting required for ruggedised fibre. The Chorus technician will install ruggedised fibre.
  • Power can be placed in the same trench, but not the same duct, ensure ECP34 (Electrical code of practice) clearances are adhered to.

For both options, advise the customer to contact B4UDIG  prior to digging, to ensure no other services are impacted.

Currently, there is no cost to customer for a second ONT but charges apply for any “While You Are Here” options.

  1.  Second ONT to be installed in a self-contained building, by definition minor dwelling, and the building has own kitchen and bathroom and is not officially sub divided (e.g. granny flat).

    Building has:
  • separate power supply and owned by the primary ONT account holder
  • own letter box or postal address. 
  • Advise the customer to follow address validation and infill processes, as Chorus has already built the network and drop offs for premises at time of build. Any new requests would be required to follow the infill process.
  • Customer can choose to sub-divide at a later date, if required. Following the infill process enables this flexibility. 
  1. Second ONT to be installed in a premise with separate address and power supply.

    Premise is sub-divided.

    If premise is greater than 200m from the boundary then the Last Step Fibre Build rules apply. 

Create address validation request in portal. Customer to provide evidence of postal address from NZ Post website and electricity authority or utility invoice.

Once address validation completed follow the infill build process

  1.  Second ONT is to be installed in a premise, with own power supply, and separate address exists in Chorus Portal.

    Premise is sub-divided.

    If premise is greater than 200m from the boundary, then the Last Step Fibre Build rules apply. 
Follow the infill build process.